Determination of Ultratrace Indicator Polychlorinated Biphenyls in Animal Feed by Gas Chromatography-Triple Quadrupole Mass Spectrometry with Isotope Internal Standards
文献类型: 外文期刊
第一作者: Wang Rui-Guo
作者: Wang Rui-Guo;Zhang Su;Dong Shu-Jun;Wei Shu-Lin;Yang Hao-Sen;Cheng Jie;Wang Pei-Long;Su Xiao-Ou;Zhang Tian-Shu
作者机构:
关键词: Indicator polychlorinated biphenyls; Feed; Gas-chromatography-tandem mass spectrometry
期刊名称:CHINESE JOURNAL OF ANALYTICAL CHEMISTRY ( 影响因子:1.134; 五年影响因子:0.909 )
ISSN: 0253-3820
年卷期: 2018 年 46 卷 12 期
页码:
收录情况: SCI
摘要: A method was developed for determination of 6 kinds of indictor polychlorinated biphenyls in animal feed by chromatography-tandem mass spectrometry (GC-MS/MS). Analytical procedure consisted of accelerate solvent extraction (ASE), lipid removal with 44% acidic silica and clean-up using a column packed with multilayer silica. The analytes were separated on a DB-5MS capillary column, detected with electron ionization (EI) and multiple reaction monitor mode (MRM), and quantified using isotope dilution technique. The result showed that the calibration curves with good correlation coefficients (R-2 >0. 999) were obtained in the concentration range of 0.1-500.0 ng/mL. The average relative response factors of PCBs in calibration solvent were 1.08-1.21, and the limit of quantification were 5.5-9.2 pg/g. The average recoveries of PCBs in animal feed at two spiked concentration levels ranged from 92.8% to 109.7% with relative standard deviations (RSDs) of 1.6%-14.8% (n = 5), and the average recoveries of quantitative internal standards were 32.6%-90.2%. Then the proposed method was successfully applied to detect the compound feed samples from the surrounding area of Beijing, and it was found that the 6 kinds of indictor PCBs were detected in all samples (n = 10) with the total concentration ranges of 54.7-191.7 pg/g, which were far below the limit standard (10 mu g/kg) of Chinese National Standards.
分类号:
- 相关文献
作者其他论文 更多>>
-
Rapid and Sensitive Detection of Acrylamide in Fried Food Based on Surface-Enhanced Raman Spectroscopy
作者:Cheng Jie;Su Xiao-ou;Wang Pei-long;Han Cai-qin;Xie Jian-chun
关键词:Surface-enhanced Raman spectroscopy; Composite nano-substrate; Fried food; Acrylamide
-
Recent Progress on the Detection of Dioxins Based on Surface-enhanced Raman Spectroscopy
作者:Cheng Jie;Wang Peilong;Su Xiaoou
关键词:surface-enhanced Raman spectroscopy; dioxins; enhanced substrates; detection
-
Simultaneous determination of antibiotics and amantadines in animal-derived feedstuffs by ultraperformance liquid chromatographic-tandem mass spectrometry
作者:Suo Decheng;Wang Peilong;Li Yang;Wang Ruiguo;Wei Shulin;Xiao Zhiming;Zhang Su
关键词:Ultraperformance liquid chromatography-tandem mass spectrometry; Antibiotics; Amantadines; Animal-derived feedstuffs
-
Determination of Melamine in Milk by Surface Enhanced Raman Scattering Technique Based on Self-Assembly Ordered Silver Nanowires
作者:Zhao Rui-Chi;Shi Lei;Wang Pei-Long;Su Xiao-Ou
关键词:Ordered silver nanowires;Melamine;Surface enhanced Raman scattering
-
Simultaneous Detection of 21 Kinds of Mycotoxins and Their Metabolites in Animal Plasma with Impurity Adsorption Purification Followed by Liquid Chromatography-Tandem Mass Spectrometry
作者:Wang Rui-Guo;Su Xiao-Ou;Wang Pei-Long;Zhang Wei;Xue Yan;Li Yu
关键词:Liquid chromatography-tandem mass spectrometry;Plasma;Mycotoxins;Residue
-
Molecularly Imprinting Polymer Electrochemical Sensor Based on Structure of Metal Organic Frameworks for Determination of Phenylethanolamine A in Swine Urine
作者:Zhang Chun-Yan;Shi Lei;Wang Pei-Long;Su Xiao-Ou
关键词:Phenylethanolamine A;Molecular imprinting polymer;Metal organic frameworks;Electrochemical sensor
-
Liquid Chromatography-Tandem Mass Spectrometry for Determination of Aflatoxin B-1, Deoxynivalenol and Zearalenone in Artificial Porcine Gastrointestinal Digestive Juice
作者:Wang Rui-Guo;Su Xiao-Ou;Fan Xia;Wang Pei-Long;Gao Zhong-Wu;Zhang Yu
关键词:Liquid chromatography-tandem mass spectrometry;Artificial porcine gastrointestinal digestive juice;Mycotoxin;Adsorbent