The quadruplex TaqMan MGB fluorescent quantitative PCR method for simultaneous detection of feline panleukopenia virus, feline herpesvirus 1, feline calicivirus and feline infectious peritonitis virus

文献类型: 外文期刊

第一作者: Wang, Haojie

作者: Wang, Haojie;Xue, Lihong;Wang, Longxi;Liu, Yixuan;Chen, Jianxing;Sun, Yue;An, Tongqing;Chen, Hongyan;Xia, Changyou;Zhang, He;Yu, Changqing

作者机构:

关键词: FPV; FHV-1; FCV; FIPV; quadruplex; TaqMan MGB fluorescent

期刊名称:FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY ( 影响因子:4.8; 五年影响因子:5.5 )

ISSN: 2235-2988

年卷期: 2025 年 15 卷

页码:

收录情况: SCI

摘要: Background Feline panleukopenia, feline calicivirus infection, feline viral rhinotracheitis, and feline infectious peritonitis are significant diseases that threaten feline health. The trend of mixed infections is increasing, and current diagnostic methods are limited in scope and unable to provide rapid, simultaneous detection of these diseases.Methods Four groups of primers and probes targeting the VP2 gene of Feline Panleukopenia virus (FPV), the TK gene of Feline Herpesvirus (FHV-1), the ORF2 gene of Feline Calicivirus (FCV), and the N gene of Feline Infectious Peritonitis Virus (FIPV) were designed. After optimizing the concentrations of primers and probes and annealing temperature, a quadruplex TaqMan MGB fluorescent quantitative PCR method was established to concurrently detect these four pathogens. Recombinant plasmid standards were constructed to establish standard curves, and the sensitivity, specificity, reproducibility, and clinical application of the assay were evaluated.Results The optimal final concentrations of primers for FPV, FHV-1, FCV, and FIPV were 0.08, 0.04, 0.06, and 0.12 mu M, respectively, and the optimal final concentrations of probes were 0.08, 0.08, 0.12, and 0.12 mu M, respectively. The best annealing temperature was 59 degrees C. No cross-reaction was observed with common pathogens in infected cats. The minimal detection limits for recombinant plasmids of T-VP2, T-TK, T-ORF2, and T-N were 50.79, 53.21, 47.91 and 41.25 copies/mu L, respectively. The R-2 values of standard curves are 0.994, 1.0, 0.998 and 0.999, respectively, and high amplification efficiencies of 105.05%, 96.28%, 98.82%, and 96.45%, respectively. The coefficient of variation for inter-batch and intra-batch tests ranged from 0.14 to 1.37%. Among 381 fecal samples from cats, the detection rates for FPV, FHV-1, FCV, and FIPV were 13.65% (52/381), 18.37% (70/381), 26.77% (102/381), and 9.71% (37/381), respectively, with a 100% agreement with previously reported methods and commercial kits.Conclusion The sensitive, specific, high-throughput, quadruplex TaqMan MGB quantitative fluorescent quantitative PCR method was successfully established for the simultaneous detection of FPV, FHV-1, FCV, and FIPV.

分类号:

  • 相关文献
作者其他论文 更多>>