Rapid and sensitive detection of beta-agonists using a portable fluorescence biosensor based on fluorescent nanosilica and a lateral flow test strip

文献类型: 外文期刊

第一作者: Song, Chunmei

作者: Song, Chunmei;Xu, Chuanlai;Zhang, Gaiping;Song, Chunmei;Zhi, Aimin;Liu, Qingtang;Yang, Jifei;Jia, Guochao;Hu, Xiaofei;Deng, Ruiguang;Zhang, Gaiping;Shervin, Jahanian;Tang, Liang

作者机构:

关键词: Fluorescence biosensor;Fluorescent nanosilica;Strip;Clenbuterol

期刊名称:BIOSENSORS & BIOELECTRONICS ( 影响因子:10.618; 五年影响因子:9.323 )

ISSN: 0956-5663

年卷期: 2013 年 50 卷

页码:

收录情况: SCI

摘要: A portable fluorescence biosensor with rapid and ultrasensitive response for Clenbuterol (CL) has been built up with fluorescent nanosilica and a lateral flow test strip. Quantitative detection of CL was realized by recording the fluorescence intensity of fluorescent nanosilica captured on the test line. The sensing results indicated that the sensitivity of the fluorescent nanosilica-based strip was better than that of conventional colloidal gold-based strips. The visual limit of detection of the strip for qualitative detection was 0.1 ng/mL while the LOD for quantitative detection could down to 0.037 ng/mL by using fluorescence biosensor. The recoveries of test samples were from 89.3% to 97.7%. The assay time for CL detection was less than 8 min, suitable for rapid testing on-site. (C) 2013 Elsevier B.V. All rights reserved.

分类号:

  • 相关文献

[1]Development of an immunochromatographic lateral flow test strip for detection of beta-adrenergic agonist Clenbuterol residues. Zhang, GP,Wang, XN,Yang, JF,Yang, YY,Xing, GX,Li, QM,Zhao, D,Chai, SJ,Guo, JQ. 2006

[2]Newly Combined Method of Molecularly Imprinted Solid-Phase Extraction with ELISA for Rapid Detection of Clenbuterol in Animal-Tissue Samples. Zheng, Sulian,Lan, Huo,Li, Rongxiu,Wu, Aibo,Zhang, Dabing,Song, Suquan,Qu, Guorun. 2009