Development of an immunochromatographic lateral flow test strip for detection of beta-adrenergic agonist Clenbuterol residues

文献类型: 外文期刊

第一作者: Zhang, GP

作者: Zhang, GP;Wang, XN;Yang, JF;Yang, YY;Xing, GX;Li, QM;Zhao, D;Chai, SJ;Guo, JQ

作者机构:

关键词: Clenbuterol;test strip;colloidal gold;immunochromatography;rapid test

期刊名称:JOURNAL OF IMMUNOLOGICAL METHODS ( 影响因子:2.303; 五年影响因子:2.556 )

ISSN: 0022-1759

年卷期: 2006 年 312 卷 1-2 期

页码:

收录情况: SCI

摘要: A rapid immunochromatographic lateral flow test strip was developed in a competitive format with the gold-conjugated monoclonal antibody to specifically determine the residues of Clenbuterol (CL), a beta-adrenergic agonist. The test strip is made up of a sample pad, a conjugate reagent pad, a test membrane containing a control line and a test line, and an absorbent pad. CL standard samples of 0, 0.1, 0.3, 0.9, 2.7, 8.1 ng/ml in swine urine were determined by the test strip. It was shown that detection limit of the test strip was as low as 0.1 ng/ml of CL and that the half of maximal inhibition concentration (IC50) in relative optical density was calculated to be 1.78 +/- 0.17 ng/ml under an optical density scanner. The sensitivity by eye measurement was 1.0 ng/ml. It takes 10 min to accomplish a test. Parallel analysis of urine samples from pigs fed with CL showed comparable results obtained from the test strip and GC-MS. Therefore, the test strip is very useful as a screening method for quantitative, semi-quantitative or qualitative detection of CL residues in swine urine. (c) 2006 Elsevier B.V. All rights reserved.

分类号:

  • 相关文献

[1]Development of a lateral-flow immunochromatographic test device for the rapid detection of difloxacin residues. Zhi, Ai-min,Li, Bin-bin,Liu, Qing-tang,Hu, Xiao-fei,Zhao, Dong,Hou, Yu-ze,Deng, Rui-guang,Zhang, Gai-ping,Li, Bin-bin,Chai, Shu-Jun. 2010

[2]Development of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Olaquindox Residues. Song, Chunmei,Liu, Qingtang,Zhi, Aimin,Yang, Jifei,Zhi, Yubao,Li, Qingmei,Hu, Xiaofei,Deng, Ruiguang,Zhang, Gaiping,Song, Chunmei,Casas, Justin,Tang, Liang.

[3]Development of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Enrofloxacin Residues. Zhao, Yinli,Zhang, Gaiping,Liu, Qingtang,Teng, Man,Yang, Jifei,Zhao, Yinli,Wang, Jianhua.

[4]Development of a lateral flow immunoassay strip for screening of sulfamonomethoxine residues. Zhang, G.,Wang, X.,Bao, Y.,Wang, Z.,Zhang, G.,Wang, X.,Yang, Y.,Luo, J.,Li, Q.,Guo, J.,Yang, J.,Xing, G.,Chai, S.,Shi, T.,Liu, Q.,Zhi, A.,Qu, M.. 2008

[5]Development of an Immunochromatographic Strip Test for the Rapid Detection of Zearalenone in Corn. Sun, Yaning,Hu, Xiaofei,Yang, Jifei,Wang, Fangyu,Wang, Yao,Deng, Ruiguang,Zhang, Gaiping,Sun, Yaning,Zhang, Yong,Zhang, Gaiping.

[6]Self-paired monoclonal antibody lateral flow immunoassay strip for rapid detection of Acidovorax avenae subsp citrulli. Zeng, Haijuan,Li, Jianwu,Zhai, Xuzhao,Song, Chunmei,Liu, Qing,Guo, Wenbo,Liang, Beibei,Zhao, Wenjun,Fan, Enguo.

[7]Rapid and sensitive detection of beta-agonists using a portable fluorescence biosensor based on fluorescent nanosilica and a lateral flow test strip. Song, Chunmei,Xu, Chuanlai,Zhang, Gaiping,Song, Chunmei,Zhi, Aimin,Liu, Qingtang,Yang, Jifei,Jia, Guochao,Hu, Xiaofei,Deng, Ruiguang,Zhang, Gaiping,Shervin, Jahanian,Tang, Liang. 2013

[8]Newly Combined Method of Molecularly Imprinted Solid-Phase Extraction with ELISA for Rapid Detection of Clenbuterol in Animal-Tissue Samples. Zheng, Sulian,Lan, Huo,Li, Rongxiu,Wu, Aibo,Zhang, Dabing,Song, Suquan,Qu, Guorun. 2009

[9]Replacing antibodies with aptamers in lateral flow immunoassay. Chen, Ailiang,Yang, Shuming,Chen, Ailiang,Yang, Shuming.

[10]Development of an immunochromatographic strip for detection of antibodies against porcine reproductive and respiratory syndrome virus. Li, Huawei,Ji, Pengchao,Zhou, Enmin,Zhang, Gaiping,Yang, Jifei,Bao, Dengke,Hou, Jie,Zhi, Yubao,Yang, Yanyan,Qiao, Songlin,Zhang, Gaiping,Zhang, Gaiping,Li, Huawei.

[11]'Green' immunochromatographic electrochemical biosensor for mercury(II). Wang, Yulong,Wang, Limin,Wang, Suyan,Yang, Mingming,Cai, Jia,Liu, Fengquan,Liu, Fengquan.

[12]Development of an isothermoal amplification-based assay for rapid visual detection of an Orf virus. Yang, Yang,Qin, Xiaodong,Wang, Guangxiang,Jin, Jiaxin,Shang, Youjun,Zhang, Zhidong,Jin, Jiaxin. 2016

[13]An On-Site, Ultra-Sensitive, Quantitative Sensing Method for the Determination of Total Aflatoxin in Peanut and Rice Based on Quantum Dot Nanobeads Strip. Ouyang, Suiyan,Zhang, Zhaowei,He, Ting,Li, Peiwu,Zhang, Qi,Chen, Xiaomei,Wang, Du,Li, Hui,Tang, Xiaoqian,Zhang, Wen,Ouyang, Suiyan,Zhang, Zhaowei,He, Ting,Li, Peiwu,Zhang, Qi,Wang, Du,Ouyang, Suiyan,Zhang, Zhaowei,He, Ting,Li, Peiwu,Li, Hui,Zhang, Wen,Ouyang, Suiyan,Zhang, Zhaowei,Li, Peiwu,Chen, Xiaomei,Tang, Xiaoqian,Zhang, Wen. 2017

[14]A rapid one-step immunochromatographic test strip for rabies detection using canine serum samples. Tao, C.,Li, G.,Tao, C..

[15]Development of an immunochromatographic test strip for simultaneous qualitative and quantitative detection of ochratoxin A and zearalenone in cereal. Sun, Yaning,Xing, Guangxu,Yang, Jifei,Wang, Fangyu,Deng, Ruiguang,Zhang, Gaiping,Hu, Xiaofei,Sun, Yaning,Zhang, Yong,Zhang, Gaiping.

[16]Rapid and Sensitive Detection of the Food Allergen Glycinin in Powdered Milk Using a Lateral Flow Colloidal Gold Immunoassay Strip Test. Wang, Yao,Li, Zhixi,Deng, Ruiguang,Zhang, Gaiping,Li, Qingmei,Yang, Jifei,Sun, Yaning,Hu, Xiaofei,Zhang, Gaiping.

[17]Rapid detection of aflatoxin B-1 on membrane by dot-immunogold filtration assay. Ye, Yang,Mo, Zhenzhen,Cheng, Wei,Yang, Sha,Wang, Xiaohong,Chen, Fusheng,Wang, Xiaohong,Chen, Fusheng,Chen, Fusheng,Zhou, Youxiang.

[18]Establishment of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Soybean Allergen beta-Conglycinin. Wang, Yao,Li, Zhaozhou,Pei, Yafeng,Hou, Yuze,Wang, Yao,Li, Qingmei,Sun, Yaning,Yang, Jifei,Yang, Yanyan,Zhi, Yubao,Deng, Ruiguang,Hu, Xiaofei.

[19]Establishment of a lateral flow colloidal gold immunoassay strip for the rapid detection of estradiol in milk samples. Yang, Xing-dong,Wang, Fang-yu,Zhang, Gai-ping,Yang, Xing-dong,Zeng, Xian-yin,Song, Chun-mei,Wu, Shu-yan,Zhang, Gai-ping.

[20]Colloidal gold-McAb probe-based rapid immunoassay strip for simultaneous detection of fumonisins in maize. Yao, Jingjing,Sun, Yaning,Li, Qingmei,Wang, Fangyu,Teng, Man,Yang, Yanyan,Deng, Ruiguang,Hu, Xiaofei.

作者其他论文 更多>>