Determination of arsenic in biological samples by slurry sampling hydride generation atomic fluorescence spectrometry using in situ dielectric barrier discharge trap
文献类型: 外文期刊
第一作者: Liu, Meitong
作者: Liu, Meitong;Liu, Tengpeng;Liu, Jixin;Mao, Xuefei;Qian, Yongzhong;Liu, Meitong;Ding, Lan;Liu, Jixin;Na, Xing;Chen, Guoying
作者机构:
期刊名称:JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY ( 影响因子:4.023; 五年影响因子:3.827 )
ISSN: 0267-9477
年卷期: 2019 年 34 卷 3 期
页码:
收录情况: SCI
摘要: In this study, the slurry sampling hydride generation (SLS-HG) system was first coupled with in situ dielectric barrier discharge atomic fluorescence spectrometry (DBD-AFS) for arsenic analysis in biological samples based on the gas phase enrichment (GPE) principle. After a simple slurry dilution with 5% HCl (v/v) for microbiological and hair samples, the as-prepared slurry was introduced into the SLS-HG unit for arsine generation under 8 g L-1 KBH4 in 1.5 g L-1 KOH. Here, the in situ DBD apparatus, comprising of the three-concentric quartz tubes, was employed to pre-concentrate arsenic to enhance the analytical sensitivity of the HG-AFS, as well as to eliminate interferences due to the dilution effect and matrix separation. This was followed by trapping with 11 kV at 110 mL min(-1) of air carrier gas, and 190 s Ar gas sweeping, arsenic was released with 13 kV at 180 mL min(-1) H-2 to the AFS for measurement. Under optimal conditions, 8 pg or 14 pg detection limits (2 mL sampling) for the microbiological or hair samples were achieved without extra pre-concentration, respectively. The linearity R-2 was 0.996 ranging from 0.05 mg L-1 to 300 mg L-1. The spiked recoveries for the real paramecium and micro diatom samples were 93-102%, and the measurements were in accordance with the certified reference material (CRM) values. The proposed SLS-HG-in situ DBD-AFS method is extremely suitable for ultratrace arsenic determination in biological samples to protect human health and environmental safety.
分类号:
- 相关文献
作者其他论文 更多>>
-
Quantitative Determination of Cd Using Energy Dispersion XRF Based on Gaussian Mixture Clustering-Multilevel Model Recalibration
作者:Gao, Yunbing;Zhao, Yanan;Pan, Yuchun;Sun, Wenbin;Zhao, Xiande;Liu, Xiaoyang;Li, Xue;Mao, Xuefei
关键词:
-
AFB1 Triggers Lipid Metabolism Disorders through the PI3K/Akt Pathway and Mediates Apoptosis Leading to Hepatotoxicity
作者:Wang, Tiancai;Li, Xiabing;Liao, Guangqin;Wang, Zishuang;Gu, Jingyi;Mu, Xiyan;Qiu, Jing;Qian, Yongzhong;Wang, Tiancai;Li, Xiabing;Liao, Guangqin;Wang, Zishuang;Gu, Jingyi;Mu, Xiyan;Qiu, Jing;Qian, Yongzhong;Han, Xiaoxu
关键词:aflatoxin B1; hepatotoxicity; apoptosis; lipid metabolism; PI3K/Akt pathway
-
Review on liquid-core waveguide technology and its application for spectroscopic analysis
作者:Mu, Bingyu;Li, Xue;Liu, Jixin;Mao, Xuefei;Mu, Bingyu;Li, Xue;Liu, Jixin;Mao, Xuefei;Liu, Jixin
关键词:liquid core waveguide; total internal reflection; long path-length; teflon AF; Spectroscopic analysis
-
Screening of Active Substances Regulating Alzheimer's Disease in Ginger and Visualization of the Effectiveness on 6-Gingerol Pathway Targets
作者:Pan, Yecan;Li, Zishu;Zhao, Xiaoyu;Du, Yang;Zhang, Lin;Lu, Yushun;Yang, Ling;Cao, Yilin;Qiu, Jing;Qian, Yongzhong;Pan, Yecan;Li, Zishu;Zhao, Xiaoyu;Du, Yang;Zhang, Lin;Lu, Yushun;Yang, Ling;Cao, Yilin;Qiu, Jing;Qian, Yongzhong
关键词:6-Gingerol; ginger; Alzheimer's disease (AD); network pharmacology; molecular dynamics (MD)
-
A portable solid sampling visualization nano-sensor for soil Cd based on "three-phase transforming" technique
作者:Liu, Tengpeng;Huang, Xudong;Wang, Chunhui;Liu, Jixin;Mao, Xuefei;Liu, Tengpeng;Huang, Xudong;Wang, Chunhui;Liu, Jixin;Mao, Xuefei;Liu, Tengpeng;Liu, Jixin;Mao, Xuefei
关键词:Cadmium; Direct solid sampling; Colorimetric sensor; Miniaturized analyzer; Soil
-
Monitoring Changes in Biochemical and Metabolite Profiles in Garlic Cloves during Storage
作者:Liu, Pingxiang;Xu, Yanyang;Weng, Rui;Qiu, Jing;Qian, Yongzhong;Liu, Pingxiang;Wang, Yutao
关键词:garlic cloves; nontargeted metabolomics; targetedmetabolomics; storage time; storage temperatures
-
A novel functionalized graphdiyne oxide membrane for efficient removal and rapid detection of mercury in water
作者:He, Qianli;Li, Xue;Chai, Weiwei;Chen, Lin;Mao, Xuefei
关键词:Graphdiyne oxide; Mercury; Adsorption; ED-XRF detection; Water