A sensitive and quantitative fluorescent multi-component immuno-chromatographic sensor for beta-agonist residues

文献类型: 外文期刊

第一作者: Wang, Peilong

作者: Wang, Peilong;Su, Xiaoou;Wang, Peilong;Su, Xiaoou;Wang, Zhi

作者机构:

关键词: beta-Agonist;Fluorescent bead;Immuno-chromatographic sensor;Multi-analyte detection

期刊名称:BIOSENSORS & BIOELECTRONICS ( 影响因子:10.618; 五年影响因子:9.323 )

ISSN:

年卷期:

页码:

收录情况: SCI

摘要: A sensitive and quantitative fluorescent multi-component immuno-chromatographic sensor was developed for detection of three beta-agonizts: clenbuterol, ractopamine and salbuterol. A competitive immune strategy between antibody conjugated fluorescent beads and beta-agonist or their antigens was employed. Each monoclonal antibody specifically recognizes it is corresponding beta-agonist in the conjugating zone. The unreacted antibodies were captured by beta-agonist antigens immobilized at three test lines in nitrocellulose membrane reaction zone. This enables simultaneous detection of 3 beta-agonizts in one single test without any further sample preparation. The test results can be obtained within 10 min. Limit of detections for clenbuterol, ractopamine and salbuterol were 0.10 ng/mL, 0.10 ng/mL and 0.09 ng/mL, respectively. Recoveries ranged from 70.0% to 100.5% and relative standard deviations were below 15%. The assay was evaluated using spiked and real samples and the results were compared with LC-MS/MS. The developed novel assay method provides a low cost, sensitive and rapid approach for on site detection of beta-agonizts. (C) 2014 Elsevier B.V. All rights reserved.

分类号: Q

  • 相关文献

[1]Multi-component immunochromatographic assay for simultaneous detection of aflatoxin B-1, ochratoxin A and zearalenone in agro-food. Li, Xin,Li, Peiwu,Zhang, Qi,Li, Ran,Zhang, Wen,Zhang, Zhaowei,Ding, Xiaoxia,Tang, Xiaoqian,Li, Xin,Zhang, Qi,Li, Ran,Zhang, Zhaowei,Li, Xin,Li, Peiwu,Li, Peiwu,Zhang, Zhaowei,Ding, Xiaoxia,Li, Peiwu,Zhang, Qi,Li, Ran,Zhang, Wen,Tang, Xiaoqian. 2013

[2]Simultaneous Determination of 14 Kinds of beta-Agonist Residues in Sheep Saliva by Ultra Performance Liquid Chramatogrephy-Tandem Mass Spectrometry. Li Yang,Su Xiao-Ou,Wang Rui-Guo,Wang Pei-Long,Zhang Wei,Chen Jie. 2013

[3]Cell-Free Expression, Purification, and Characterization of the Functional beta(2)-Adrenergic Receptor for Multianalyte Detection of beta-Agonists. Wang, Jian,Liu, Yuan,Han, Zhengzheng,Wang, Wei,Liu, Yang,Wei, Dong,Wang, Jian,Liu, Yuan,Zhang, Junhua,Huang, Wei. 2017

[4]Direct measurement of beta-agonists in swine hair extract in multiplexed mode by surface-enhanced Raman spectroscopy and microfluidic paper. Dou, Bin,Luo, Yong,Gao, Zhigang,Zhao, Weijie,Lin, Bingcheng,Dou, Bin,Luo, Yong,Gao, Zhigang,Zhao, Weijie,Chen, Xu,Shi, Bo,Du, Yuguang,Lin, Bingcheng.

作者其他论文 更多>>