您好,欢迎访问北京市农林科学院 机构知识库!

A Lateral Flow Strip Based on a Truncated Aptamer-Complementary Strand for Detection of Type-B Aflatoxins in Nuts and Dried Figs

文献类型: 外文期刊

作者: Zhao, Zhilei 1 ; Wang, He 1 ; Zhai, Wenlei 2 ; Feng, Xiaoyuan 2 ; Fan, Xia 3 ; Chen, Ailiang 3 ; Wang, Meng 1 ;

作者机构: 1.Hebei Univ, 180 Wusi Dong Rd, Baoding 071002, Hebei, Peoples R China

2.Beijing Res Ctr Agr Stand & Testing, 9 Middle Rd Shuguanghuayuan, Beijing 100097, Peoples R China

3.Chinese Acad Agr Sci, Inst Qual Stand & Testing Technol Agroprod, Key Lab Agroprod Qual & Safety, Beijing 100081, Peoples R China

关键词: Type-B aflatoxins; lateral flow; aptamer; complementary strand; nuts and dried figs

期刊名称:TOXINS ( 影响因子:4.546; 五年影响因子:4.8 )

ISSN:

年卷期: 2020 年 12 卷 2 期

页码:

收录情况: SCI

摘要: Type-B aflatoxins (AFB(1) and AFB(2)) frequently contaminate food, especially nuts and fried figs, and seriously threaten human health; hence, it is necessary for the newly rapid and sensitive detection methods to prevent the consumption of potentially contaminated food. Here, a lateral flow aptasensor for the detection of type-B aflatoxins was developed. It is based on the use of fluorescent dye Cy5 as a label for the aptamer, and on the competition between type-B aflatoxins and the complementary DNA of the aptamer. This is the first time that the complementary strand of the aptamer has been used as the test line (T-line) to detect type-B aflatoxins. In addition, the truncated aptamer was used to improve the affinity with type-B aflatoxins in our study. Therefore, the lengths of aptamer and cDNA probe were optimized as key parameters for higher sensitivity. In addition, binding buffer and organic solvent were investigated. The results showed that the best pair for achieving improved sensitivity and accuracy in detecting AFB(1) was formed by a shorter aptamer (32 bases) coupled with the probe complementary to the AFB(1) binding region of the aptamer. Under the optimal experimental conditions, the test strip showed an excellent linear relationship in the range from 0.2 to 20 ng/mL with a limit of detection of 0.16 ng/mL. This aptamer-based strip was successfully applied to the determination of type-B aflatoxins in spiked and commercial peanuts, almonds, and dried figs, and the recoveries of the spiked samples were from 93.3%-112.0%. The aptamer-complementary strand-based lateral flow test strip is a potential alternative tool for the rapid and sensitive detection of type-B aflatoxins in nuts and dried figs. It is of help for monitoring aflatoxins to avoid the consumption of unsafe food.

  • 相关文献
作者其他论文 更多>>