Ultrasound-assisted dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-fluorescence detection for sensitive determination of biogenic amines in rice wine samples
文献类型: 外文期刊
作者: Huang, Ke-Jing 1 ; Wei, Cai-Yun 1 ; Liu, Wei-Li 1 ; Xie, Wan-Zhen 1 ; Zhang, Jun-Feng 2 ; Wang, Wei 3 ;
作者机构: 1.Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
2.Henan Acad Agr Sci, Res Ctr Agr Stand & Inspect Technol, Chengzhou 450002, Peoples R China
3.Yancheng Inst Technol, Sch Chem & Biol Engn, Yancheng 224003, Peoples R China
关键词: Ultrasound-assisted dispersive liquid-liquid microextraction;Biogenic amines;2;6-Dimethyl-4-quinolinecarboxylic acid;N-hydroxysuccinimide ester;High-performance liquid chromatography-fluorescence detection;Rice wine samples
期刊名称:JOURNAL OF CHROMATOGRAPHY A ( 影响因子:4.759; 五年影响因子:4.302 )
ISSN:
年卷期:
页码:
收录情况: SCI
摘要: Ultrasound-assisted dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-fluorescence detection was used for the extraction and determination of three biogenic amines including octopamine. tyramine and phenethylamine in rice wine samples. Fluorescence probe 2.6-dimethyl-4-quinolinecarboxylic acid N-hydroxysuccinimide ester was applied for derivatization of biogenic amines. Acetonitrile and 1-octanol were used as disperser solvent and extraction solvent, respectively. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, ultrasonication time and centrifuging time were optimized. After extraction and centrifuging, analyte was injected rapidly into high-performance liquid chromatography and then detected with fluorescence. The calibration graph of the proposed method was linear in the range of 5-500 mu g mL(-1) (octopamine and tyramine) and 0.025-2.5 mu g mL(-1) (phenethylamine). The relative standard deviations were 2.4-3.2% (n = 6) and the limits of detection were in the range of 0.02-5 ng mL(-1). The method was applied to analyze the rice wine samples and spiked recoveries in the range of 95.42-104.56% were obtained. The results showed that ultrasound-assisted dispersive liquid-liquid microextraction was a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of biogenic amines.
- 相关文献
作者其他论文 更多>>
-
Changes of nitrogen deposition in China from 1980 to 2018
作者:Wen, Zhang;Xu, Wen;Li, Qi;Han, Mengjuan;Tang, Aohan;Zhang, Ying;Zhang, Fusuo;Liu, Xuejun;Luo, Xiaosheng;Shen, Jianlin;Wang, Wei;Li, Kaihui;Pan, Yuepeng;Zhang, Lin;Li, Wenqing;Collett, Jeffery Lee, Jr.;Zhong, Buqing;Wang, Xuemei;Goulding, Keith
关键词:Reactive nitrogen; Atmospheric deposition; Ammonia; Air pollution; Emission control
-
A highly sensitive and selective biosensing strategy for the detection of Pb2+ ions based on GR-5 DNAzyme functionalized AuNPs
作者:Wang, Hai-Bo;Wang, Lan;Huang, Ke-Jing;Xu, Shu-Ping;Wang, Ling-Ling;Liu, Yan-Ming;Wang, Hai-Bo;Wang, Hong-Qi
关键词:
-
LC Analysis of Aliphatic Primary Amines and Diamines After Derivatization with 2,6-Dimethyl-4-quinolinecarboxylic Acid N-Hydroxysuccinimide Ester
作者:Huang, Ke-Jing;Wei, Cai-Yun;Xie, Wan-Zhen;Liu, Yan-Ming;Chen, Yong-Hong;Zhang, Jun-Feng
关键词:Column liquid chromatography;Fluorescence detection;Aliphatic primary;amines and diamines;2;6-Dimethyl-4-quinolinecarboxylic acid;N-hydroxysuccinimide ester