关键词: gas chromatography; triple quadrupole mass spectrometry; stable isotope dilution assay; methyleugenol; food

期刊名称:JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE ( 影响因子:3.638; 五年影响因子:3.802 )

ISSN: 0022-5142

年卷期: 2018 年 98 卷 9 期

页码:

收录情况: SCI

摘要: BACKGROUNDMethyleugenol is a common phenylpropanoid compound found in many plants and has been widely used as a flavoring agent in people's daily life. In this study, a stable isotope dilution assay-coupled gas chromatography/triple quadrupole mass spectrometry (SIDA-GC/MS/MS) method was developed for the quantitative determination of methyleugenol in food samples. Methyleugenol-D-3 was synthesized and used as an isotope internal standard for the determination of methyleugenol. The QuEChERS (quick, easy, cheap, effective, rugged and safe) method was applied to the clean-up of food sample extracts. Confirmation and quantification were carried out by GC/MS/MS. RESULTSThe analytical performance of the method was validated. The determination range of methyleugenol was linear from 4 to 500 mu g L-1. Method detection limits for solid food samples, semi-solid food samples and liquid beverages were 50, 50 and 1 mu g kg(-1) respectively. Satisfactory recoveries in the range 94.29-100.27% were obtained. Intra- and inter-day precision was also validated and the values were all lower than 9%. The method was successfully applied to quantify methyleugenol in different kinds of food samples. CONCLUSIONThis article describes a new method for the accurate quantification of methyleugenol in food samples based on a stable isotope labeling-assisted GC/MS/MS method. Methyleugenol-D-3 was synthesized and used as an isotope internal standard for the determination of methyleugenol. Excellent results were generated with the method, and the detection sensitivity and accuracy of the method were good. (c) 2018 Society of Chemical Industry

  • 相关文献
作者其他论文 更多>>