您好,欢迎访问中国水产科学研究院 机构知识库!

Gold Immunochromatography Assay-A Newly Rapid Detection Technique for Aquatic Products

文献类型: 外文期刊

作者: Wang, Yuan 1 ; Yu, Hui-juan 1 ; Qian, Bei-lei 1 ; Cai, You-qiong 1 ; Huang, Dong-mei 1 ; Hui, Yun-hua 1 ; Liu, Huan 2 ; M 1 ;

作者机构: 1.Minist Agr PR China, CAFS Aquat Prod Qual Inspect & Test Ctr Shanghai, East China Sea Fisheries Res Inst, Shanghai 200090, Peoples R China

2.Chinese Acad Fishery Sci, Qual & Standards Res Ctr, Beijing 100141, Peoples R China

关键词: Gold immunochromatography assay;rapid detection;aquatic products

期刊名称:MATERIAL DESIGN, PROCESSING AND APPLICATIONS, PARTS 1-4

ISSN: 1022-6680

年卷期: 2013 年 690-693 卷

页码:

收录情况: SCI

摘要: Gold immunochromatography assay (GICA) technique has the following characteristics: rapid and simple, high sensitivity, good specificity, no auxiliary equipment, ease of interpreting results, and satisfactory stability. The technique has become one of the most rapid and sensitive immunological detection methods, which is widely used in medical, biological and other fields. The article focuses on the basic principles and technical characteristics of GICA, and briefly describes the applications and future perspectives in the rapid detection of aquatic products.

  • 相关文献

[1]Sensitive Determination of Eight Paralytic Shellfish Poisoning Toxins in Aquatic Products by LC-MS-MS method. Feng Bing,Cai Youqiong,Zhang Xiaoling,Yu Huijuan. 2013

[2]Dietary risk ranking for residual antibiotics in cultured aquatic products around Tai Lake, China. Song, Chao,Zhang, Cong,Qiu, Liping,Fan, Limin,Wu, Wei,Meng, Shunlong,Hu, Gengdong,Chen, Jiazhang,Song, Chao,Zhang, Cong,Qiu, Liping,Fan, Limin,Wu, Wei,Meng, Shunlong,Hu, Gengdong,Chen, Jiazhang,Song, Chao,Li, Le,Zhang, Cong,Qiu, Liping,Fan, Limin,Wu, Wei,Meng, Shunlong,Hu, Gengdong,Chen, Jiazhang,Li, Le,Liu, Ying,Mao, Aimin. 2017

[3]Silylation Derivatization for the Detection of Hydroxylated Polychlorinated Bipheny in Aquatic Products by GC/MS. Shi, Yong-fu,Lin, Hong,Huang, Dong-mei,Cai, You-qiong,Wang, Yuan. 2009

[4]Silylation Derivatization for the Detection of Hydroxylated Polychlorinated Bipheny in Aquatic Products by GC/MS. Yong-fu Shi,You-qiong Cai,Hong Lin,Dong-mei Huang,Yuan Wang. 2009

[5]Development of a rapid cyprinid herpesvirus 2 detection method by loop-mediated isothermal amplification. Liang, L. -G.,Xie, J.,Luo, D.,Luo, D..

[6]Comparative study of graphene nanosheet- and multiwall carbon nanotube-based electrochemical sensor for the sensitive detection of cadmium. Wu, Lidong,Fu, Xiaochen,Liu, Huan,Li, Jincheng,Song, Yi. 2014

作者其他论文 更多>>