您好,欢迎访问中国热带农业科学院 机构知识库!

A simple and sensitive fluoroimmunoassay based on the nanobody-alkaline phosphatase fusion protein for the rapid detection of fenitrothion

文献类型: 外文期刊

作者: Chen, Zi-Jian 1 ; Huang, Ai-Jun 1 ; Dong, Xiu-Xiu 4 ; Zhang, Yi-Feng 5 ; Zhu, Lin 6 ; Luo, Lin 5 ; Xu, Zhen-Lin 5 ; Wang, Hongwu 1 ;

作者机构: 1.Zhaoqing Univ, Sch Food & Pharmaceut Engn, Zhaoqing, Peoples R China

2.Minist Agr & Rural Affairs, Lab Qual & Safety Risk Assessment Agroprod Zhaoqin, Zhaoqing, Peoples R China

3.Guangdong Engn Technol Res Ctr Food & Agr Prod Saf, Zhaoqing, Peoples R China

4.Jiangsu Univ, Key Lab Modern Agr Equipment & Technol, Sch Agr Engn, Minist Educ, Zhenjiang, Peoples R China

5.South China Agr Univ, Guangdong Prov Key Lab Food Qual & Safety, Guangzhou, Peoples R China

6.Chinese Acad Trop Agr Sci, Guangzhou Expt Stn, Guangzhou, Peoples R China

关键词: fluoroimmunoassay; fenitrothion; carbon dots; nanobody-alkaline phosphatase fusion protein; rapid detection

期刊名称:FRONTIERS IN SUSTAINABLE FOOD SYSTEMS ( 影响因子:4.7; 五年影响因子:5.4 )

ISSN:

年卷期: 2023 年 7 卷

页码:

收录情况: SCI

摘要: Immunoassay is a powerful tool for the rapid detection of small harmful organic molecules. In this study, a simple and sensitive fluoroimmunoassay (FIA) based on a nanobody-alkaline phosphatase fusion protein (VHHjd8-ALP) and blue-emissive carbon dots (bCDs) was developed for the rapid detection of fenitrothion. The bCDs were synthesized using the one-step hydrothermal method. Citric acid and urea were used as carbon and nitrogen sources, respectively. The synthesized bCDs were characterized by fluorescence spectrum, high-resolution transmission electron microscopy, x-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. After one step of competitive immunoassay, the VHHjd8-ALP bound to the microplate and catalyzed the substrate p-nitrophenylphosphate (pNPP) into p-nitrophenol (pNP); the latter can quench the blue of bCDs due to an inner-filter effect. After condition optimization, an FIA calibration curve was finally created, which showed an IC50 value of 16.25 ng/mL and a limit of detection (LOD) of 0.19 ng/mL. Compared with the pNPP-based one-step conventional indirect competitive enzyme-linked immunoassay (icELISA), the developed FIA showed an 11-fold sensitivity improvement. Furthermore, the analysis period of FIA only takes approximately 55 min, which was obviously faster than that of the conventional icELISA. The recovery test showed recoveries from 81.8 to 119% with fruits and vegetable samples, which verified the practicability and accuracy of the developed FIA.

  • 相关文献
作者其他论文 更多>>