您好,欢迎访问新疆农垦科学院 机构知识库!

Selecting specific aptamers that bind to ovine pregnancy-associated glycoprotein 7 using real serum sample-assisted FluMag-SELEX to develop magnetic microparticle-based colorimetric aptasensor

文献类型: 外文期刊

作者: Lu, Chunxia 1 ; Liu, Changbin 2 ; Zhou, Qin 1 ; Chen, Xia 3 ; Li, Hongmin 3 ; Wang, Shuanghui 1 ; Guo, Yanhua 2 ;

作者机构: 1.Yangtze Normal Univ, Life Sci & Technol Inst, Chongqing 408100, Peoples R China

2.Xinjiang Acad Agr & Reclamat Sci, Inst Anim Husb & Vet Sci, Shihezi 832000, Peoples R China

3.Xinjiang Acad Agr & Reclamat Sci, Anal & Testing Ctr, Shihezi 832000, Peoples R China

关键词: Aptamers; Hybridization chain reaction; Pregnancy-associated glycoproteins; Pregnancy diagnosis; SELEX

期刊名称:ANALYTICA CHIMICA ACTA ( 影响因子:6.911; 五年影响因子:6.467 )

ISSN: 0003-2670

年卷期: 2022 年 1191 卷

页码:

收录情况: SCI

摘要: The pregnancy-associated glycoproteins (PAGs) have been widely used as biomarkers for the early diagnosis of pregnancy in cattle and sheep. This study aimed to obtain the single-stranded DNA aptamers that specifically bound to ovine pregnancy-associated glycoprotein 7 (ovPAG7) with high affinity (Kd = 9.8-32.4 nM) using real serum sample-assisted FluMag-systematic evolution of ligands by exponential enrichment (SELEX). Subsequently, the selected aptamers were applied to fabricate an ultrasensitive colorimetric aptasensor for ovPAG7 detection based on functionalized magnetic microparticles and hybridization chain reaction. Under the optimized conditions, the colorimetric aptasensor exhibited a broad linear range (0.2 -500 ng mL-1), low detection limit (0.081 ng mL-1), good recovery rate (94.5-109.1%), and high repeatability (relative standard deviation of 4.02-8.16%) in ovPAG7-spiked serum. Furthermore, this aptasensor was applied to measure the ovPAG7 in serum samples of ewes for pregnancy diagnosis. Blood samples were collected from Chinese Merino ewes on days 22, 28 after artificial insemination (AI) for ovPAG7 detection, respectively. Transrectal ultrasonography diagnosis of pregnancy 45 days after AI was the reference (gold) standard for all PAG tests. Diagnostic sensitivity, specificity, and accuracy of the proposed aptasensor were 95.8, 87.5, and 92.5% at day 22 and 95.8, 90.6, and 93.7% at day 28, respectively. The degree of agreement (Kappa) between developed aptasensor and ultrasonography diagnosis 22 and 28 day after AI were higher than 0.8. These results illustrated that the aptasensor was proved to be a sensitive, reliable and cost-effective way of measuring PAG and might be a useful means of pregnancy detection in ewes. (c) 2021 Published by Elsevier B.V.

  • 相关文献