期刊名称:JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY ( 影响因子:5.279; 五年影响因子:5.269 )

ISSN:

年卷期:

页码:

收录情况: SCI

摘要: A rapid immunochromatographic test strip has been developed for the detection of zearalenone (ZEN) residues in corn. For this purpose, a specific anti-ZEN monoclonal antibody (mAb), 4A3-F9, was obtained and identified. ZEN coupled to bovine serum albumin (BSA) via 1,4-butanediol diglycidyl ether was prepared as immunogen. The mAb showed low cross-reactivity with five ZEN analogues. Using an antibody preparation with a titer of >= 1:5.12 x 10(5), the cross-reactivity (CR) of the anti-ZEN monoclonal antibody with four of the analogues was <496, except for zearalanone, which was 53.121%. The recovery rates of ZEN in spiked corn samples were in the range of 91.30-97.07% with coefficients of variation <5.32%. An immunochromatographic strip was developed using the specific anti-ZEN monoclonal antibody and applied to the screening of corn samples for ZEN residues. The test could be accomplished within 5-10 min. The sensitivity of the test strip in corn sample extract was confirmed to be 20 mu g/kg by unaided visual assessment, and the IC50 was calculated as 3.4 ng/mL using a test strip reader. The test strip, analyzed by unaided visual assessment and strip reader, showed very good agreement with competitive indirect ELISA and high-performance liquid chromatography (HPLC) analysis for naturally contaminated corn samples.

  • 相关文献

[1]Development of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Olaquindox Residues. Song, Chunmei,Liu, Qingtang,Zhi, Aimin,Yang, Jifei,Zhi, Yubao,Li, Qingmei,Hu, Xiaofei,Deng, Ruiguang,Zhang, Gaiping,Song, Chunmei,Casas, Justin,Tang, Liang.

[2]Development of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Enrofloxacin Residues. Zhao, Yinli,Zhang, Gaiping,Liu, Qingtang,Teng, Man,Yang, Jifei,Zhao, Yinli,Wang, Jianhua.

[3]Development of a lateral flow immunoassay strip for screening of sulfamonomethoxine residues. Zhang, G.,Wang, X.,Bao, Y.,Wang, Z.,Zhang, G.,Wang, X.,Yang, Y.,Luo, J.,Li, Q.,Guo, J.,Yang, J.,Xing, G.,Chai, S.,Shi, T.,Liu, Q.,Zhi, A.,Qu, M.. 2008

[4]Development of an immunochromatographic test strip for simultaneous qualitative and quantitative detection of ochratoxin A and zearalenone in cereal. Sun, Yaning,Xing, Guangxu,Yang, Jifei,Wang, Fangyu,Deng, Ruiguang,Zhang, Gaiping,Hu, Xiaofei,Sun, Yaning,Zhang, Yong,Zhang, Gaiping.

[5]Development of an immunochromatographic lateral flow test strip for detection of beta-adrenergic agonist Clenbuterol residues. Zhang, GP,Wang, XN,Yang, JF,Yang, YY,Xing, GX,Li, QM,Zhao, D,Chai, SJ,Guo, JQ. 2006

[6]Rapid and Sensitive Detection of the Food Allergen Glycinin in Powdered Milk Using a Lateral Flow Colloidal Gold Immunoassay Strip Test. Wang, Yao,Li, Zhixi,Deng, Ruiguang,Zhang, Gaiping,Li, Qingmei,Yang, Jifei,Sun, Yaning,Hu, Xiaofei,Zhang, Gaiping.

[7]Establishment of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Soybean Allergen beta-Conglycinin. Wang, Yao,Li, Zhaozhou,Pei, Yafeng,Hou, Yuze,Wang, Yao,Li, Qingmei,Sun, Yaning,Yang, Jifei,Yang, Yanyan,Zhi, Yubao,Deng, Ruiguang,Hu, Xiaofei.

[8]Development of a colloidal gold-based strip test for the detection of chlorothalonil residues in cucumber. Yang, Xingdong,Zeng, Xianyin,Yang, Xingdong,Zhang, Gaiping,Wang, Fangyu,Wang, Yinbiao,Hu, Xiaofei,Li, Qingmei,Jia, Guochao,Liu, Zhen,Wang, Yao,Deng, Ruiguang,Zhang, Gaiping.

[9]Colloidal gold-McAb probe-based rapid immunoassay strip for simultaneous detection of fumonisins in maize. Yao, Jingjing,Sun, Yaning,Li, Qingmei,Wang, Fangyu,Teng, Man,Yang, Yanyan,Deng, Ruiguang,Hu, Xiaofei.

[10]Establishment of a lateral flow colloidal gold immunoassay strip for the rapid detection of estradiol in milk samples. Yang, Xing-dong,Wang, Fang-yu,Zhang, Gai-ping,Yang, Xing-dong,Zeng, Xian-yin,Song, Chun-mei,Wu, Shu-yan,Zhang, Gai-ping.

[11]Development of an immunochromatographic assay for the rapid detection of chlorpyrifos-methyl in water samples. Hua, Xiude,Qian, Guoliang,Hu, Baishi,Fan, Jiaqin,Qin, Na,Li, Gang,Wang, Yuyan,Liu, Fengquan,Yang, Jifei.

[12]Development of a lateral-flow immunochromatographic test device for the rapid detection of difloxacin residues. Zhi, Ai-min,Li, Bin-bin,Liu, Qing-tang,Hu, Xiao-fei,Zhao, Dong,Hou, Yu-ze,Deng, Rui-guang,Zhang, Gai-ping,Li, Bin-bin,Chai, Shu-Jun. 2010

[13]Development of a one-step strip test for the diagnosis of chicken infectious bursal disease. Zhang, GP,Li, QM,Yan, YY,Guo, JQ,Li, XW,Deng, RG,Xiao, ZJ,Xing, GX,Yang, JF,Zhao, D,Cai, SJ,Zang, WM. 2005

[14]A SERS-based multiple immuno-nanoprobe for ultrasensitive detection of neomycin and quinolone antibiotics via a lateral flow assay. Shi, Qiaoqiao,Zhang, Gaiping,Shi, Qiaoqiao,Sun, Yaning,Deng, Ruiguang,Teng, Man,Li, Qingmei,Yang, Yanyan,Hu, Xiaofei,Zhang, Gaiping,Shi, Qiaoqiao,Huang, Jie,Zhang, Zhijun,Zhang, Gaiping. 2018

[15]Characterization of a monoclonal antibody specific for human peripheral myelin protein 22 and its use in immunohistochemical studies of the fetal and adult nervous system. Gregson, Norman A.,Zhang, Gaiping,Pritchard, Jane,Wang, Aiping,Sanvito, Lara,Hayday, Adrian C.,Hughes, Richard A. C.. 2007

[16]Eu3+-labeled IgG-based time-resolved fluoroimmunoassay for highly sensitive detection of aflatoxin B-1 in feed. Zhang, Gaiping,Hu, Xiaofei,Yao, Jingjing,Wang, Fangyu,Yin, Mengqi,Sun, Yaning,Hu, Mei,Shi, Qiaoqiao,Zhang, Gaiping. 2018

作者其他论文 更多>>