Novel cross-linkable fluorescent probe with oriented antibody to enhance lateral immunoassay strip for the detection of acetamiprid

文献类型: 外文期刊

作者: Li, Donghan 1 ; Dong, Haowei 1 ; Li, Zhengtao 1 ; Wang, Haifang 4 ; Sun, Jiashuai 1 ; Huang, Jingcheng 1 ; Li, Peisen 1 ; Zhou, Shuxian 1 ; Zhai, Shengxi 1 ; Zhao, Mingxin 5 ; Sun, Xia 1 ; Guo, Yemin 1 ;

作者机构: 1.Shandong Univ Technol, Sch Agr Engn & Food Sci, 266 Xincun Xilu, Zibo 255049, Shandong, Peoples R China

2.Shandong Prov Engn Res Ctr Vegetable Safety & Qual, 266 Xincun Xilu, Zibo 255049, Shandong, Peoples R China

3.Zibo City Key Lab Agr Prod Safety Traceabil, 266 Xincun Xilu, Zibo 255049, Shandong, Peoples R China

4.Beijing Univ Chinese Med, Dongzhimen Hosp, Beijing 100700, Peoples R China

5.Gansu Acad Agr Sci, Inst Fruit & Floriculture, Lanzhou 730070, Gansu, Peoples R China

关键词: Time-resolved fluorescent microsphere; Goat anti-mouse IgG; Vegetables; Immunochromatographic platform; 1-ethyl-(3-dimethylaminopropyl) carbodiimide; hydrochloride

期刊名称:JOURNAL OF HAZARDOUS MATERIALS ( 影响因子:11.3; 五年影响因子:12.4 )

ISSN: 0304-3894

年卷期: 2024 年 476 卷

页码:

收录情况: SCI

摘要: Time-resolved fluorescent lateral immunoassay strip (TRFLIS) is a reliable and rapid method for detecting acetamiprid. However, its sensitivity is often affected by the structural patterns and stability of the fluorescent probe. Researchers have shown significant interests in using goat anti-mouse IgG (GaMIgG) which is indirectly bound to time-resolved fluorescent microsphere (TRFM) and antibody. This allowed for oriented modification of the antibody. However, the stability of fluorescent probe in this binding mode remained unexplored. Herein, 1ethyl-(3-dimethylaminopropyl) carbodiimide hydrochloride was innovatively used as a cross-linking agent to enhance the binding of antibody to GaMIgG, which improved the stability of the fluorescent probe. Under optimal working conditions, this strategy exhibited a wide linear response range of 5-700 ng/mL. Its limit of detection (LOD) was 0.62 ng/mL, the visual LOD was 5 ng/mL, and the limit of quantification (LOQ) of 2.06 ng/ mL. Additionally, under tomato matrix, leek matrix and Chinese cabbage matrix, the linear response ranges were 5-400, 5-300, and 5-700 ng/mL, with LODs of 0.16, 0.60, and 0.41 ng/mL, with LOQs of 0.53, 2.01 and 1.37 ng/mL, respectively. In conclusion, this strategy effectively reduced the dosage of acetamiprid antibody compared with TRFM directly linking acetamiprid antibody, and greatly increased the sensitivity of TRFLIS. Meanwhile, it demonstrated outstanding specificity and accuracy in acetamiprid detection and had been successfully applied to vegetable samples. This method enables rapid and accurate detection of large-volume samples by combining qualitative and quantitative methods. As such, it has great potential in the development of low-cost and high-performance immunochromatographic platforms.